For more than 55 years, manufacturers across multiple industries that involve hazardous materials have trusted SANDPIPER to protect people, equipment, the environment and the material being pumped.
The SANDPIPER 1½" S15 Non-Metallic AODD Pump provides unsurpassed fluid containment in the event a diaphragm is breached.
This leak-free pump is designed to be driven by compressed air or nitrogen.
Environmental concerns: When fluids (like those listed below) escape to the environment, significant time and effort is required on clean up and material recovery. Additionally, the costs of downtime, lost production, manpower, equipment replacement, disposal fees and fines can be excessive. Preventing leaks when handling these substances provides a more efficient operation and avoids the damaging effects of environmental and human exposure to these toxic fluids.
High cost of lost fluid: When fluids (like those listed below) escape to the environment, the cost of losing them is significant. Lost fluid means lost profit.
Fluids that need to be contained: Even non-toxic fluids, like clean water, can create hazards, annoyances and safety concerns if people are in or around the area surrounding a pump when a diaphragm fails. When dealing with toxic and hazardous fluids, the need to contain leaks goes from a nuisance to a critical safety need.
To determine chemical compatibility with this pump, please refer to our Chemical Compatibility Guide. Material of construction options include: polypropylene and PVDF, with elastomer TPE (thermoplastic elastomers) and PTFE options in diaphragms and check valves.
Port Size | 1½" ANSI Flange or PN10 40mm DIN Flange |
Capacity | 0 to 100 gpm (378 lpm) |
Air Distribution Valve | No-lube, no-stall design |
Solids-Handling | Up to .47" (12 mm) |
Heads Up To | 100 psi or 231 ft. of water (7 bar or 70 meters) |
Displacement/Stroke | .43 gallons (1.63 liters) |
Max Operating Pressure | 100 psi (7 bar) |
Shipping Weight Polypropylene PVDF Conductive Polypropylene Polypropylene Spill Containment PVDF Spill Containment |
82 lbs (37 kg) 112 lbs (51 kg) 85 lbs (38 kg) 149 lbs (68 kg) 194 lbs (88 kg) |
SANDPIPER can provide you with a CAD file to save time and improve the quality of your final design, as well as reduce measurement and documentation packet errors. Contact us today to request yours.
Get the expertise you need to overcome AODD pumping challenges and find the answers that will set you up for success. Here's how:
© 2022 SANDPIPER Pump | Portal Login | IDEX | Privacy Policy | Terms of Access | Patents | Website by SyncShow